서브메뉴
검색
Miniature Mass Spectrometer Based Point-Of-Care Methods for Analysis of Biofluids- [electronic resource]
Miniature Mass Spectrometer Based Point-Of-Care Methods for Analysis of Biofluids- [electronic resource]
- 자료유형
- 학위논문
- Control Number
- 0016932873
- International Standard Book Number
- 9798379851811
- Dewey Decimal Classification Number
- 545
- Main Entry-Personal Name
- Pandey, Sangeeta.
- Publication, Distribution, etc. (Imprint
- [S.l.] : Purdue University., 2022
- Publication, Distribution, etc. (Imprint
- Ann Arbor : ProQuest Dissertations & Theses, 2022
- Physical Description
- 1 online resource(124 p.)
- General Note
- Source: Dissertations Abstracts International, Volume: 85-01, Section: A.
- General Note
- Advisor: Cooks, R. Graham.
- Dissertation Note
- Thesis (Ph.D.)--Purdue University, 2022.
- Restrictions on Access Note
- This item must not be sold to any third party vendors.
- Summary, Etc.
- 요약Miniature mass spectrometers are in a phase of rapid development due to their potential in offering simple yet powerful solutions for a wide variety of unmet biomedical needs. In particular, the combination of ambient ionization methods with miniature mass spectrometers offers an attractive solution for improving patient outcomes and reducing the healthcare burden on patients as well as clinicians opposed to current methods for disease prognosis and diagnosis.There has been a rapid expansion in the commercial offerings of miniature mass spectrometers from commercial vendors, both large and small, including Purspec, Bayspec, MassTech, Waters, and Advion. Despite the large number of instruments that have been made available and the success of many of these systems with analysis of a broad range of biological matrices, much work remains to perform bioanalysis of complex molecules with concentrations that often lie in the ng/mL-µg/mL range. Miniaturization of mass spectrometers is accompanied by design simplifications in comparison to benchtop instruments, so that sacrifices are often made in terms of performance. The figure of merit that is compromised, of course, depends on the design of the instrument itself. Thus, in addition to a good understanding of the operation of the mass spectrometer, it is crucial that the ionization method for the analyte be chosen judiciously, and that the method is suitably optimized to be able to perform the measurements to obtain high quality data for trace analysis.The custom built Mini-12 miniature MS systems at Purdue University is one such miniature mass spectrometer that can be used for making on-site measurements. In this work, I have described my efforts to perform trace analysis of a range of molecules (tenofovir diphosphate, cabotegravir, rilpivirine, and phosphatidylethanol) relevant to HIV treatment and prevention with the Mini-12 system. Based on the most favorable set of conditions for developing a particular assay, method performance parameters are listed for each of the applications described. In all the above applications, the desired detection limits are met by adopting a broad range of strategies with the focus of keeping the method amenable to use at the point-of-care, i.e., ensuring that sample preparation is completed in 4 minutes. The proof-of-concept results obtained with the custom built Mini-12 mass spectrometer at Purdue University lays the groundwork to (i) encourage the introduction of miniature mass spectrometer-based assays for the molecules listed in a clinical setting and (ii) extend the use of miniature mass spectrometer-based assays for other therapeutic regimens that require longitudinal monitoring.
- Subject Added Entry-Topical Term
- Universal Serial Bus.
- Subject Added Entry-Topical Term
- Mass spectrometry.
- Subject Added Entry-Topical Term
- Software.
- Subject Added Entry-Topical Term
- Plasma.
- Subject Added Entry-Topical Term
- Human immunodeficiency virus--HIV.
- Subject Added Entry-Topical Term
- Arson.
- Subject Added Entry-Topical Term
- Power.
- Subject Added Entry-Topical Term
- Cellulose.
- Subject Added Entry-Topical Term
- Ions.
- Subject Added Entry-Topical Term
- Solvents.
- Subject Added Entry-Topical Term
- Real time.
- Subject Added Entry-Topical Term
- Atmospheric pressure.
- Subject Added Entry-Topical Term
- Medical research.
- Subject Added Entry-Topical Term
- Drugs.
- Subject Added Entry-Topical Term
- Biomarkers.
- Subject Added Entry-Topical Term
- Alcohol.
- Subject Added Entry-Topical Term
- Vacuum technology.
- Subject Added Entry-Topical Term
- Chromatography.
- Subject Added Entry-Topical Term
- Blood.
- Subject Added Entry-Topical Term
- Metabolites.
- Subject Added Entry-Topical Term
- Explosives.
- Subject Added Entry-Topical Term
- Interfaces.
- Subject Added Entry-Topical Term
- Analytical chemistry.
- Subject Added Entry-Topical Term
- Atmospheric sciences.
- Subject Added Entry-Topical Term
- Chemistry.
- Subject Added Entry-Topical Term
- Criminology.
- Subject Added Entry-Topical Term
- Medicine.
- Added Entry-Corporate Name
- Purdue University.
- Host Item Entry
- Dissertations Abstracts International. 85-01A.
- Host Item Entry
- Dissertation Abstract International
- Electronic Location and Access
- 로그인을 한후 보실 수 있는 자료입니다.
- Control Number
- joongbu:641920