본문

서브메뉴

Venous Perfusion Source Mapping "In Reverse" With Magnetic Resonance Imaging.
ข้อมูลเนื้อหา
Venous Perfusion Source Mapping "In Reverse" With Magnetic Resonance Imaging.
자료유형  
 학위논문
Control Number  
0017163643
International Standard Book Number  
9798384455073
Dewey Decimal Classification Number  
621.3
Main Entry-Personal Name  
Karasan, Ekin.
Publication, Distribution, etc. (Imprint  
[S.l.] : University of California, Berkeley., 2024
Publication, Distribution, etc. (Imprint  
Ann Arbor : ProQuest Dissertations & Theses, 2024
Physical Description  
117 p.
General Note  
Source: Dissertations Abstracts International, Volume: 86-04, Section: B.
General Note  
Advisor: Lustig, Michael.
Dissertation Note  
Thesis (Ph.D.)--University of California, Berkeley, 2024.
Summary, Etc.  
요약Magnetic resonance imaging (MRI) is a versatile medical imaging modality, which can be used for a variety of applications, including imaging soft tissue structure, measuring functional brain activity by probing blood oxygenation, assessing complex tissue dynamics, and quantifying tissue susceptibility. Measuring complex tissue dynamics such as perfusion and blood flow can offer essential information for diagnosis and provide insights into biophysical functions. Non-contrast enhanced methods to image these dynamics are particularly advantageous as they minimize the risk for patients and improve patient comfort.While MRI tools for probing blood flow and perfusion are well-established for studying cerebral arterial disorders, the knowledge on the venous drainage mechanism of the brain is much more limited. This is largely attributed to the person-to-person variability in the cerebral venous physiology and the limitations of the current imaging technologies. Venous abnormalities play an important role in several important vascular and neurological conditions. Furthermore, venous effects also contribute significantly to functional MRI (fMRI) based on blood oxygenation level dependent (BOLD) contrast by reducing the spatial specificity of the BOLD signal.Digital subtraction angiography (DSA) is currently the gold standard to image the venous system, however, it is an invasive procedure that has life-threatening risks. Primary non-invasive and non-contrast enhanced tools to probe the venous system with MRI are phase-contrast (PC) MRI, which probes the instantaneous velocity of blood and time of flight (TOF), which relies on inflow effects. TOF MRI is limited to imaging the venous structure and provides minimal information on flow dynamics. PC MRI requires very large velocity encoding gradients to capture slower flows, significantly increasing echo times, potentially leading to phase offset errors and reducing the accuracy of the measured velocities. Therefore, neither of the techniques can probe the venous system in its entirety.To address current limitations in venous imaging, this dissertation proposes a novel venous perfusion source mapping method using Displacement Spectrum (DiSpect) MRI, a non-contrast method that uses blood water as an endogenous contrast agent. This technique encodes spatial information into the magnetization of blood water spins during tagging and remotely detects it once the tagged blood reaches the imaging region - often near the brain's surface, where the signal-to-noise ratio is 3-4x higher. Through repeated spin-tagging and Fourier encoding, this method can resolve the sources of blood water entering the imaging slice across short (10ms) to long (3s) evolution times, effectively capturing venous perfusion sources in reverse. Blood sources can be traced regardless of their path and velocity, enabling measurement of slow blood flow in smaller veins and potentially in capillary beds.The dissertation first introduces the theory behind DiSpect MRI and describes its application in venous perfusion source mapping in the superior cerebral veins. Next, the sensitivity of the proposed perfusion source mapping technique is established through perfusion modulation using caffeine and its specificity is demonstrated by measuring local perfusion changes during functional activation. Finally, the technique is validated with flow phantom experiments, and several advancements in acquisition techniques are presented.
Subject Added Entry-Topical Term  
Electrical engineering.
Subject Added Entry-Topical Term  
Biomedical engineering.
Subject Added Entry-Topical Term  
Medical imaging.
Subject Added Entry-Topical Term  
Medicine.
Index Term-Uncontrolled  
Magnetic resonance imaging
Index Term-Uncontrolled  
Biophysical functions
Index Term-Uncontrolled  
Phase-contrast
Index Term-Uncontrolled  
Digital subtraction angiography
Added Entry-Corporate Name  
University of California, Berkeley Electrical Engineering & Computer Sciences
Host Item Entry  
Dissertations Abstracts International. 86-04B.
Electronic Location and Access  
로그인을 한후 보실 수 있는 자료입니다.
Control Number  
joongbu:658532
New Books MORE
최근 3년간 통계입니다.

ค้นหาข้อมูลรายละเอียด

  • จองห้องพัก
  • 캠퍼스간 도서대출
  • 서가에 없는 책 신고
  • โฟลเดอร์ของฉัน
วัสดุ
Reg No. Call No. ตำแหน่งที่ตั้ง สถานะ ยืมข้อมูล
TQ0034749 T   원문자료 열람가능/출력가능 열람가능/출력가능
마이폴더 부재도서신고

* จองมีอยู่ในหนังสือยืม เพื่อให้การสำรองที่นั่งคลิกที่ปุ่มจองห้องพัก

해당 도서를 다른 이용자가 함께 대출한 도서

Related books

Related Popular Books

도서위치